If your device is not designed with a single IP method, please follow the procedures below to verify the IP change process. All IP addresses below must be distinct. Ensure you keep detailed modification records during the process.

Change Sequence Application Type Instructions
Visible Light Camera IP For network camera input, confirm camera IP modification first Change via web login
Thermal Infrared Camera IP For network camera input, confirm camera IP modification first Change via web login
Digital Interface Camera No action required
Serial Server IP Modify IP via web login. Default IP: 192.168.1.66
If modified previously, check Serial Server IP in TVMS client
Change via web login. Default credentials: admin/12345678
Do not modify configurations beyond IP address
Laser Fill Light/
Laser Rangefinder
Serial Server IP
Modify IP via web login. Default IP: 192.168.1.88
If modified previously, check Laser Rangefinder IP in TVMS client
Change via web login. Default credentials: admin/12345678
Do not modify configurations beyond IP address
Tofu Module IP 1. Modify local IP via TVMS client
2. Re-add login for new IP
3. Modify Serial Server IP configuration
4. For network camera input devices: modify stream URL
5. Update Laser Rangefinder IP
Execute steps sequentially.
Skip irrelevant device types

Recommend using router NAT mapping or single-IP modules for IP mapping. In such cases, only modify the mapped address.